AS-100
Infant Incubator

A stationary neonatal incubator with skin-mode and air-mode temperature control and a display showing several values simultaneously.

  • Temperature range 25–38 °C
  • Humidity control 30–95 %RH
  • Double-wall construction reduces heat loss
  • High-temperature and power-failure alarms
AS-200
Radiant Warmer

A radiant warmer for delivery rooms and neonatal procedure rooms, with multi-level heat output adjustment.

  • Heat output adjustable 0–100 %
  • Skin-temperature servo mode
  • Height-adjustable bassinet
  • Suited to neonatal resuscitation
AS-300
Transport Incubator

An incubator for transporting infants between delivery rooms, operating theatres and hospitals, powered by an internal battery.

  • Battery backup for continuous operation
  • Vibration-resistant structure
  • Mounts onto trolleys and stretchers
  • Clear battery status display
AS-400
Phototherapy Unit

A phototherapy unit for neonatal jaundice that delivers uniform light intensity across the skin surface.

  • Adjustable light intensity
  • Long-life LED lamps
  • Mounts on an incubator or a separate stand
  • Treatment timer
PART 02

Clinical Applications

Choose according to the tier of the facility and the patient profile it handles; our sales team can advise on the basis of actual use.

Neonatal intensive care unit (NICU)

The AS-100 incubator is the mainstay for low-birth-weight infants requiring round-the-clock environmental control, with the AS-400 added when jaundice is present.

Delivery room and operating theatre

The AS-200 delivers immediate warmth after birth, during assessment and neonatal resuscitation.

Inter-hospital transfer

The AS-300 maintains body temperature during ambulance transfer — the period in which an infant loses heat most readily.

Community hospitals

Start with one or two incubators and a phototherapy unit to cover normal deliveries, and refer complex cases onward.

PART 03

Technical Data by Model

Each model has its own table. The values shown are those declared by the manufacturer in the model datasheet, not independent test results — please confirm the values your clinical use depends on in the quotation before ordering.

AS-100Infant Incubator · Infant Incubator & Radiant Warmer
Air temperature range25 – 37 °C, adjustable in 0.1 °C steps
Temperature stability±0.5 °C under controlled conditions
Relative humidity30 – 75 % RH (evaporative water system)
Infant weight per manualUp to 4 kg for this model
ConstructionDouble-walled, hood opens on two sides
Alarm systemHigh/low temperature, power failure, fan fault, door open
AS-200Radiant Warmer · Infant Incubator & Radiant Warmer
Air temperature range25 – 38 °C, adjustable in 0.1 °C steps
Temperature stability±0.3 °C under controlled conditions
Relative humidity30 – 85 % RH, servo-controlled
Infant weight per manualUp to 5 kg for this model
ControlSkin-temperature servo-control with two skin sensors
Alarm systemAdds humidity and skin-temperature alarms
AS-300Transport Incubator · Infant Incubator & Radiant Warmer
Air temperature range25 – 38 °C
Relative humidity30 – 90 % RH, automatic
Infant weight per manualUp to 6 kg for this model
Additional functionsIntegrated weighing, tray-based X-ray imaging (sub-model dependent)
DisplayColor touchscreen with historical temperature trends
Reference standardsIEC 60601-1, IEC 60601-1-2, IEC 60601-2-19
AS-400Phototherapy Unit · Infant Incubator & Radiant Warmer
Air temperature range25 – 39 °C
Relative humidity30 – 90 % RH, automatic
Infant weight per manualUp to 8 kg for this model
Combined operationDesigned to work with the phototherapy bassinet in the same set
Data loggingSeven-day trend recording with data export
Reference standardsIEC 60601-1, IEC 60601-1-2, IEC 60601-2-19, IEC 60601-2-50
Prepared by Aegismed Product DivisionLast updated 16 November 2026
Technical reviewer The manufacturer's Clinical Engineering department — the reviewer's name and sign-off date are stated in the Technical Data Sheet supplied with the quotation
Source references Datasheet and Instructions for Use (IFU) for every model listed above — the full PDF files are available by email
Disclaimer Information on patient suitability (for example use with neonates) and consumable replacement intervals must follow the instructions for use of that model and the judgement of the treating physician; it is not the marketing copy on this page
PART 04

Frequently Asked Questions

Answers are based on the instructions for use and datasheets of the models listed on this page. For anything concerning neonatal patients or consumable replacement intervals, please confirm against the manual supplied with the device and the judgement of the treating physician.

What is the difference between an incubator and a radiant warmer?
An incubator encloses the infant in a controlled environment and suits longer-term care and humidity control. A radiant warmer has an open top for immediate access to the infant, which suits delivery rooms and resuscitation.
How often should the device be calibrated?
We recommend calibrating the temperature sensors at least once a year, and after every repair or replacement of parts related to the temperature control system.
Do you provide documentation for tender submissions?
Yes. User manuals and technical documentation are available, together with CE and ISO 13485 certificates for tender submission.
What are the lead time and spare parts arrangements?
Production typically takes 20–35 working days after order confirmation. Key spare parts are ready to ship within the lead time agreed in the contract.
Contact us

Request a quote — Neonatal Incubators

Tell us the unit quantity, destination country and preferred payment terms. We will reply with a quotation and the document list within one business day.

Emailwanlinfirecontrol@163.com
Phone+86 132 6167 7119
WhatsApp+86 132 6167 7119
Business hoursMon–Sat 09:00–18:00 (GMT+8)